Building Technology Glossary
50 terms that come up in BMS projects, integration work and energy discussions, explained in plain language.
A
- Air Handling Unit (AHU)
- The equipment that conditions and moves air through a building: fans, filters, coils and dampers in one housing. Most of a BMS sequence of operations is written around how the AHU responds to zone demand.
- Analog Input / Analog Output (AI / AO)
- Point types that carry a continuous value, such as a temperature reading (input) or a valve position command (output). Their binary counterparts, BI and BO, carry on/off states.
B
- BACnet
- An open data communication protocol for building automation, maintained as an ASHRAE and ISO standard. It defines how controllers describe their data as objects and how they exchange it.
- BACnet MS/TP
- The serial version of BACnet, running over RS-485 twisted pair. Common at the field level for VAV boxes and unitary controllers; slower than BACnet/IP and sensitive to wiring and addressing mistakes.
- BACnet Secure Connect (BACnet/SC)
- An addition to BACnet that carries traffic over TLS-encrypted WebSocket connections with certificate-based authentication, addressing the lack of security in classic BACnet/IP.
- Brick Schema
- An open semantic model that describes building equipment, points and the relationships between them, so software can understand that a sensor measures the supply air of a specific AHU.
- Building Automation System (BAS)
- The controllers, network and software that monitor and control mechanical and electrical systems. Often used interchangeably with BMS.
- Building Management System (BMS)
- The supervisory layer of building automation: graphics, scheduling, alarms and trends across HVAC, lighting and other systems. Some people use BMS for the whole system and BAS for the controls underneath.
C
- Chiller
- A machine that produces chilled water for cooling, either water-cooled with a cooling tower or air-cooled. Chiller plants are usually the largest single electrical load in a large commercial building.
- Commissioning (Cx)
- The process of verifying that building systems are installed and perform as designed. Good commissioning includes functional testing of sequences, not just checking that equipment powers on.
- Controller (DDC)
- A direct digital control device that reads inputs, runs control logic and drives outputs. Ranges from a small unitary controller on a VAV box to a programmable plant controller.
- Current Transformer (CT)
- A sensor clamped around a conductor to measure current for energy metering. Choosing a CT rated far above the actual load is one of the most common causes of poor metering accuracy.
D
- Demand Charge
- The part of a commercial electricity bill based on the highest power drawn during a billing period, rather than total energy used. A single short peak can set the charge for the whole month.
- Demand-Controlled Ventilation (DCV)
- A strategy that adjusts outdoor air to actual occupancy, usually measured with CO2 sensors, instead of ventilating for full design occupancy all day.
- Demand Response
- Reducing or shifting electrical load when the grid operator or utility asks, often in exchange for payments or lower tariffs.
- Digital Twin
- A digital model of a building linked to live operational data. Useful twins combine geometry, equipment relationships and real-time points; a 3D model alone is not a twin.
E
- Economizer
- A damper and control arrangement that uses cool outdoor air for free cooling when conditions allow. Stuck or poorly controlled economizers are among the most frequent faults found by FDD tools.
- Edge Computing
- Processing data close to where it is produced, on a gateway or local server in the building, instead of sending everything to the cloud. It reduces latency and keeps local control working during internet outages.
- Energy Management System (EMS)
- Software and metering focused on measuring, analyzing and reducing energy use. It may sit on top of a BMS or be a separate system.
F
- Fan Coil Unit (FCU)
- A small terminal unit with a fan and a heating and/or cooling coil serving one space, common in hotels, apartments and offices.
- Fault Detection and Diagnostics (FDD)
- Software that analyzes BMS and meter data with rules or models to find equipment faults and control problems, ideally before occupants notice them.
G
- Gateway (Protocol Converter)
- A device that translates between protocols, for example exposing data from a manufacturer-specific HVAC bus as BACnet or Modbus points.
H
- Heat Pump
- Equipment that moves heat rather than generating it, providing heating and often cooling. Commercial heat pumps are central to most building electrification plans.
I
- Indoor Air Quality (IAQ)
- The condition of indoor air in terms of CO2, particulates, volatile organic compounds, humidity and temperature, and its effect on comfort and health.
- Interoperability
- The ability of systems from different suppliers to exchange data and work together without custom development on every project.
- Internet of Things (IoT)
- Networked sensors and devices that report data or accept commands over IP or low-power wireless networks. In buildings, typically occupancy, environmental and asset-tracking sensors.
K
- KNX
- An open standard for home and building control, widely used for lighting, shading and room control, especially in Europe.
L
- LoRaWAN
- A low-power, long-range wireless network protocol. Suited to battery sensors that send small amounts of data, such as temperature or occupancy, across large buildings.
M
- M-Bus (Meter-Bus)
- A European standard for reading utility meters (heat, water, gas and electricity) over a two-wire bus or wirelessly.
- Matter
- An open connectivity standard for smart home devices that runs over IP networks such as Wi-Fi and Thread, designed to make devices from different makers work together.
- Modbus (RTU / TCP)
- A simple, widely supported industrial protocol for reading and writing registers. RTU runs over serial lines; TCP runs over Ethernet. It has no built-in data model or security.
- MQTT
- A lightweight publish-and-subscribe messaging protocol common in IoT platforms. Devices publish to topics on a broker, and any authorized application can subscribe.
O
- Occupancy Sensor
- A sensor that detects whether a space is in use (presence) or how many people are in it (people counting). The two answer different questions and are often confused in specifications.
- Open Protocol
- A communication protocol whose specification is publicly available, so any manufacturer can implement it. Being open does not guarantee that two implementations will work together without testing.
- Operational Technology (OT)
- Hardware and software that monitor and control physical equipment, as opposed to IT systems that handle data. Building controls are OT and need their own security approach.
P
- PID Loop
- The proportional-integral-derivative control logic used to hold a value, such as supply air temperature, at a setpoint. Poorly tuned loops cause hunting, wasted energy and wear.
- Point
- A single data item in a BMS, such as a temperature, a status or a setpoint. A large building can have tens of thousands of them.
- Point Naming Convention
- The agreed structure for naming BMS points so that people and software can tell what each one is and where it belongs. Inconsistent naming is a common reason analytics projects stall.
- Project Haystack
- An open initiative that defines tags and conventions for describing building and equipment data, making it easier for software to interpret points without manual mapping.
- Proprietary Protocol
- A communication method controlled by a single manufacturer. Integrating it with other systems usually requires that manufacturer's gateway or published interface.
R
- Retrofit
- Upgrading systems in an existing building, for example replacing controls or adding sensors, while the building is usually still occupied.
S
- Sequence of Operations
- The written description of how a system should behave in every mode: start-up, normal operation, alarms and shutdown. It is the reference for programming and for commissioning tests.
- Setpoint
- The target value a control loop tries to maintain, such as 22 °C room temperature or a duct static pressure.
- Smart Building
- A building whose systems share data and are managed together to improve comfort, efficiency and operations. The label means little unless the data is actually used.
- Submetering
- Measuring energy or water use below the main utility meter, by tenant, floor or system, for billing or operational insight.
- Supervisory Controller
- A device that sits between field controllers and the BMS front end, handling network management, schedules, alarms and trend storage for a building or a section of it.
T
- Thrive Score™
- The BuildingTech Insights rating framework that scores technology solutions on seven criteria, from compatibility to value and ROI, to make comparisons consistent.
- Trend Log
- A record of a point's values over time, kept by a controller or the BMS. Trends are the raw material for troubleshooting and analytics, so their intervals and retention matter.
V
- Variable Air Volume (VAV)
- A system that varies the amount of supply air to each zone with a damper in a terminal box, rather than varying air temperature alone.
- Variable Refrigerant Flow (VRF)
- A heat pump system that circulates refrigerant directly to multiple indoor units and varies the flow to match each zone's demand. Integration with a BMS usually goes through a gateway.